RayBiotech/人ANGII EIA/1平板试剂盒/EIA-ANGII-1
商品编号:
EIA-ANGII-1
品牌:
RayBiotech
市场价:
¥0.00
美元价:
0.00
产品分类:
漩涡震荡仪
公司分类:
Vortex_oscillator
联系Q Q:
3392242852
电话号码:
4000-520-616
电子邮箱:
info@ebiomall.com
商品介绍
Antigen Information
Accession Number:
- P01019
Gene ID:
- 183
Gene Symbols:
- AGT
- SERPINA8
Protein Name & Synonyms:
Angiotensinogen (Serpin A8) [Cleaved into: Angiotensin-1 (Angiotensin 1-10) (Angiotensin I) (Ang I) Angiotensin-2 (Angiotensin 1-8) (Angiotensin II) (Ang II) Angiotensin-3 (Angiotensin 2-8) (Angiotensin III) (Ang III) (Des-Asp[1]-angiotensin II) Angiotensin-4 (Angiotensin 3-8) (Angiotensin IV) (Ang IV) Angiotensin 1-9 Angiotensin 1-7 Angiotensin 1-5 Angiotensin 1-4]
Assay Format
Detection Range:
0.1-1,000 pg/ml
Recommended Dilution (serum & plasma):
Human: 2X / Mouse: 2X / Rat: 2X
Sensitivity:
0.3 pg/ml
Specificity:
This kit can theoretically detect all active angiotensins, including ANGI, ANGII, ANGIII and ANGIV as well as inactive angiotensinogen.Cross Reactivity: This EIA kit shows no cross-reactivity with any of the cytokines tested: Ghrelin, Nesfatin, NPY and APC.
Number of Targets Detected:
1
Species Detected:
- Human
- Mouse
- Rat
Compatible Sample Types:
- Serum
Design Principle:
- Competition-based
Method of Detection:
Colorimetric
Quantitative/Semi-Quantitative:
- Quantitative
Solid Support:
96-well Microplate
Product Specifications
Size:
1, 2, or 5 x 96-Well Strip Microplate Kit
Introduction
Angiotensin, a key player in the renin-angiotensin system, is a peptide hormone that causes vasoconstriction, increased blood pressure, and release of aldosterone from the adrenal cortex. It is derived from the precursor molecule angiotensinogen produced in the liver.Angiotensin II is formed from Angiotensin I, which is removed of two terminal residues by the enzyme Angiotensin-converting enzyme (ACE). Angiotensin II acts as an endocrine, autocrine/ paracrine, and intracrine hormone. Angiotensin II is degraded to angiotensin III by angiotensinases that are located in red blood cells and the vascular beds of most tissues. It has a half-life in circulation of around 30 seconds, while in tissue, it may be as long as 15-30 minutes.The effect of obesity on Angiotensin II has recently been reported. Obese patients show heightened renal vasodilation to blockade of the renin-angiotensin system, suggesting deficits in vascular responses to angiotensin II. This may due to increased reactivity of renal vasoconstriction to ANG II. Angiotensin II has been associated with a number of important physiological processes in heart, brain, adrenal gland and kidney. For cardiovascular effect, Angiotensin II is a potent direct vasoconstrictor, constricting arteries and veins and increasing blood pressure. It is also the most important Gq stimulator of the heart during hypertrophy. For neural effects, Angiotensin II increases thirst sensation (dipsogen) through the subfornical organ (SFO) of the brain, decreases the response of the baroreceptor reflex, and increases the desire for salt. It increases secretion of ADH in the posterior pituitary and secretion of ACTH in the anterior pituitary. For adrenal effects, Angiotensin II acts on the adrenal cortex, causing it to release aldosterone. For renal effects, Angiotensin II has a direct effect on the proximal tubules to increase Na+ absorption.
Product Features
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
Application Notes
Kit Components
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Standard Peptide
- Assay Diluent(s)
- Biotinylated Peptide
- HRP-Streptavidin
- TMB One-Step Substrate
- Stop Solution
- Assay Diagram
- Positive Control Sample
- Capture Antibody
- User Manual
Other Materials Required
- Distilled or deionized water
- Precision pipettes to deliver 2 µl to 1 ml volumes
- Adjustable 1-25 ml pipettes for reagent preparation
- 100 ml and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Orbital shaker
- Aluminum foil
- Saran Wrap
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- SigmaPlot software (or other software that can perform four-parameter logistic regression models)
Protocol Outline
- Prepare all reagents, samples and standards as instructed.
- Add 100 µl detection antibody to each well.
- Incubate 1.5 h at RT or O/N at 4°C.
- Add 100 µl standard or sample to each well.
- Incubate 2.5 h at RT.
- Add 100 µl prepared streptavidin solution.
- Incubate 45 min at RT.
- Add 100 µl TMB One-Step Substrate Reagent to each well.
- Incubate 30 min at RT.
- Add 50 µl Stop Solution to each well.
- Read plate at 450 nm immediately.
Storage/Stability
Standard, Biotinylated Angiotensin II peptide, and Positive Control should be stored at -20°C after arrival. Avoid multiple freeze-thaws. The remaining kit components may be stored at 4°C. Opened Microplate Wells and antibody (Item N) may be stored for up to 1 month at 2° to 8°C. Return unused wells to the pouch containing desiccant pack and reseal along entire edge.
- Bigelman E., Cohen L., Aharon-Hananel G., et al. Pathological presentation of cardiac mitochondria in a rat model for chronic kidney disease. PLoS One. 2018 Jun 11;13(6):e0198196. doi: 10.1371/journal.pone.0198196Species: RatSample type: Plasma
- Pandey VG., Jain S., Rana A., et al. Dexamethasone promotes hypertension by allele-specific regulation of the human angiotensinogen gene. J Biol Chem. 2015 Feb 27;290(9):5749-58. doi: 10.1074/jbc.M114.601922. Species: MouseSample type: Plasma
- Najafipour H., Vakili A., Shahouzehi B., et al. Investigation of changes in apelin receptor mRNA and protein expression in the myocardium and aorta of rats with two-kidney, one-clip (2K1C) Goldblatt hypertension. J Physiol Biochem. 2015 Jun;71(2):165-75. doi: 10.1007/s13105-015-0394-zSpecies: RatSample type: Serum
- Zheng Z., Cheng C., Dong R., et al. Advanced glycation end products upregulate angiopoietin-like protein 4 expression by activating the renin-angiotensin system in endothelial cells. Biomed Rep. 2015 Jul;3(4):578-582Species: HumanSample type: Conditioned Media
- Youn J., Zhou J, Cai H. Bone Morphogenic Protein 4 Mediates NOX1-Dependent eNOS Uncoupling, Endothelial Dysfunction, and COX2 Induction in Type 2 Diabetes Mellitus. Mol Endocrinol. 2015 Aug;29(8):1123-33. doi: 10.1210/ME.2014-1313. Species: MouseSample type: Plasma
- Xue Q., Chen P., Xiongxiong L., et al. Maternal High-Fat Diet Causes a Sex-Dependent Increase in AGTR2 Expression and Cardiac Dysfunction in Adult Male Rat Offspring. Biol Reprod. 2015 Aug;93(2):49. doi: 10.1095/biolreprod.115.129916Species: RatSample type: Plasma
- Sugimura-Wakayama Y., Katafiri W., Osugi M., et al. Peripheral Nerve Regeneration by Secretomes of Stem Cells from Human Exfoliated Deciduous Teeth. Stem Cells Dev. 2015 Nov 15;24(22):2687-99. doi: 10.1089/scd.2015.0104.Species: RatSample type: Plasma
- Joshi S., Gupta N., Khan R., et al. Interrelationship between angiogenesis, inflammation and oxidative stress in Indian patients with multiple myeloma. Clin Transl Oncol. 2016 Feb;18(2):132-7. doi: 10.1007/s12094-015-1344-5. Species: HumanSample type: Serum
- Hou J., Yan P., Guo T., et al. Cardiac stem cells transplantation enhances the expression of connexin 43 via the ANG II/AT1R/TGF-beta1 signaling pathway in a rat model of myocardial infarction. Exp Mol Pathol. 2015 Dec;99(3):693-701. doi: 10.1016/j.yexmp.2015.11.013Species: RatSample type: Tissue Lysate
- Dhar, Priyanka, Shashi B. Singh, and Vijay K. Sharma. "Autonomic Cardiovascular Responses in Acclimatized Lowlanders on Prolonged Stay at High Altitude: A Longitudinal Follow Up Study." PLoS One. PLoS One, 03 Jan. 2014. Web.Species: HumanSample type: Serum
Prev
123
NextSUNY Buffalo11/14/2018, 02:44 PM
品牌介绍
raybiotech致力于开发、研制、生产及销售以抗体芯片、ELISA/EIA、抗原抗体为主的酶免产品。率先开发了高品质的抗体和蛋白质芯片技术平台,蛋白质芯片能够同时有效地分析生物样品中参与炎症、血管生长、细胞生长、细胞凋亡及信号转导等数百种蛋白的表达水平。近400页的产品目录,主要涉及蛋白质芯片、抗体芯片、抗体、免疫试剂、诊断试剂等近万种,拥有先进的技术优势。许多发表在Nature、Nature Medicine、 Cell、 PNAS、Lancet等世界顶级期刊上的文章中均使用了瑞博奥的产品,公司的芯片技术和产品质量都得到了广泛的肯定。
联络我们